TROUBLESHOOTING
1. Unit fails to turn on.
Hose or power connection problem.
Check the power cables for secure connection and make sure the hoses to your
pureWash are connected to the correct ttings, and that your cold water faucet
is turned on.
2. Flashing red light.
Oxidizing Module has failed.
Contact your dealer or or visit www.pureWash.com/Support for a replacement.
3. Simultaneous Flashing Blue Light and Sounding Alarm.
Power Supply Has Failed.
Contact your dealer or or visit www.pureWash.com/Support for a replacement.
4. No ozone smell in laundry.
Check the viewing glass for bubbles as it may be producing ozone but not
injecting it into the water correctly. If no bubbles are present, the Oxidizing Module
may have failed.
Contact your dealer or or visit www.pureWash.com/Support for a replacement.
5. No bubbles are being created.
Incorrect pressure before/after Venturi or Venturi is plugged.
First check for obstruction between the pureWash and the washer (inlet screen
to washer). Ensure house pressure at the supply valve has minimum of 40psi. If this
fails to correct the problem then backush your unit by switching the hoses on the
pureWash hose ttings and place the “Cold Water In” hose into the basin or bucket
to drain to clear the Venturi. Then return hoses to proper connections.